High Performance Liquid Chromatography:Article Title: Macrocyclic indole derivatives
Article Snippet: Method P11: Instrument: Pump: Labomatic HD-5000 or HD-3000, Head HDK 280, lowpressure gradient module ND-B1000; Manual injection valve: Rheodyne 3725i038; Detector Knauer Azura UVD 2.15: Collector: Labomatic Labocol Vario-4000; Column: Chromatorex RP C-18 10 μm, 125×30 mm; Solvent A: water+0.2 Vol-% ammonia (32%).
Article Title: PTEFb inhibiting macrocyclic compounds
Article Snippet: Preparative HPLC Instrument: pump: Labomatic HD-5000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; solvent A: water+0.2 vol-% ammonia (32%), solvent B: acetonitrile; gradient: 0.00-0.50 min 15% B (150 mL/min), 0.50-6.00 min 15-55% B (150 mL/min), 6.00-6.10 min 55-100% B (150 mL/min), 6.10-8.00 min 100% B (150 mL/min); UV-detection (256 nm).
Article Title: 3-oxo-6-heteroaryl-2-phenyl-2,3-dihydropyridazine-4-carboxamides
Article Snippet: Preparativ HPLC Methods Instrument: pump: Labomatic HD-3000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; eluent; gradient; UV-Detection.
Article Title: PTEFB inhibiting macrocyclic compounds
Article Snippet: Preparative HPLC Instrument: pump: Labomatic HD-5000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; solvent A: water+0.1 vol-% formic acid (99%), solvent B: acetonitrile; gradient: 0.00-0.50 min 40% B (150 mL/min), 0.50-6.00 min 40-80% B (150 mL/min), 6.00-6.10 min 80-100% B (150 mL/min), 6.10-8.00 min 100% B (150 mL/min); UV-Detection (242 nm).
Article Title: Sulphur substituted 3-oxo-2,3-dihydropyridazine-4-carboxamides
Article Snippet: Preparative HPLC Methods Instrument: pump: Labomatic HD-3000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; eluent; gradient; UV-Detection.
Injection:Article Title: Macrocyclic indole derivatives
Article Snippet: Method P11: Instrument: Pump: Labomatic HD-5000 or HD-3000, Head HDK 280, lowpressure gradient module ND-B1000; Manual injection valve: Rheodyne 3725i038; Detector Knauer Azura UVD 2.15: Collector: Labomatic Labocol Vario-4000; Column: Chromatorex RP C-18 10 μm, 125×30 mm; Solvent A: water+0.2 Vol-% ammonia (32%).
Article Title: PTEFb inhibiting macrocyclic compounds
Article Snippet: Preparative HPLC Instrument: pump: Labomatic HD-5000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; solvent A: water+0.2 vol-% ammonia (32%), solvent B: acetonitrile; gradient: 0.00-0.50 min 15% B (150 mL/min), 0.50-6.00 min 15-55% B (150 mL/min), 6.00-6.10 min 55-100% B (150 mL/min), 6.10-8.00 min 100% B (150 mL/min); UV-detection (256 nm).
Article Title: 3-oxo-6-heteroaryl-2-phenyl-2,3-dihydropyridazine-4-carboxamides
Article Snippet: Preparativ HPLC Methods Instrument: pump: Labomatic HD-3000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; eluent; gradient; UV-Detection.
Article Title: PTEFB inhibiting macrocyclic compounds
Article Snippet: Preparative HPLC Instrument: pump: Labomatic HD-5000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; solvent A: water+0.1 vol-% formic acid (99%), solvent B: acetonitrile; gradient: 0.00-0.50 min 40% B (150 mL/min), 0.50-6.00 min 40-80% B (150 mL/min), 6.00-6.10 min 80-100% B (150 mL/min), 6.10-8.00 min 100% B (150 mL/min); UV-Detection (242 nm).
Article Title: Sulphur substituted 3-oxo-2,3-dihydropyridazine-4-carboxamides
Article Snippet: Preparative HPLC Methods Instrument: pump: Labomatic HD-3000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; eluent; gradient; UV-Detection.
Solvent:Article Title: Macrocyclic indole derivatives
Article Snippet: Method P11: Instrument: Pump: Labomatic HD-5000 or HD-3000, Head HDK 280, lowpressure gradient module ND-B1000; Manual injection valve: Rheodyne 3725i038; Detector Knauer Azura UVD 2.15: Collector: Labomatic Labocol Vario-4000; Column: Chromatorex RP C-18 10 μm, 125×30 mm; Solvent A: water+0.2 Vol-% ammonia (32%).
Article Title: PTEFb inhibiting macrocyclic compounds
Article Snippet: Preparative HPLC Instrument: pump: Labomatic HD-5000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; solvent A: water+0.2 vol-% ammonia (32%), solvent B: acetonitrile; gradient: 0.00-0.50 min 15% B (150 mL/min), 0.50-6.00 min 15-55% B (150 mL/min), 6.00-6.10 min 55-100% B (150 mL/min), 6.10-8.00 min 100% B (150 mL/min); UV-detection (256 nm).
Article Title: 3-oxo-6-heteroaryl-2-phenyl-2,3-dihydropyridazine-4-carboxamides
Article Snippet: Preparativ HPLC Methods Instrument: pump: Labomatic HD-3000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; eluent; gradient; UV-Detection.
Article Title: PTEFB inhibiting macrocyclic compounds
Article Snippet: Preparative HPLC Instrument: pump: Labomatic HD-5000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; solvent A: water+0.1 vol-% formic acid (99%), solvent B: acetonitrile; gradient: 0.00-0.50 min 40% B (150 mL/min), 0.50-6.00 min 40-80% B (150 mL/min), 6.00-6.10 min 80-100% B (150 mL/min), 6.10-8.00 min 100% B (150 mL/min); UV-Detection (242 nm).
Article Title: Sulphur substituted 3-oxo-2,3-dihydropyridazine-4-carboxamides
Article Snippet: Preparative HPLC Methods Instrument: pump: Labomatic HD-3000, head HDK 280, lowpressure gradient module ND-B1000; manual injection valve: Rheodyne 3725i038; detector: Knauer Azura UVD 2.15; collector: Labomatic Labocol Vario-4000; column: Chromatorex RP C-18 10 μm, 125×30 mm; eluent; gradient; UV-Detection.
|